Insurers handling industrial property policies typically require CE certificates, classification reports from an accredited fire-testing laboratory, and declarations of performance for every fire-rated door in a passive fire protection strategy. These documents demonstrate that each door assembly has been independently tested, classified under EN 13501-2, and placed on the market in compliance with the EU Construction Products Regulation. The sections below address the most common documentation questions that arise when preparing or reviewing an industrial fire door file for insurance purposes.
Which fire door documents do insurers typically request?
Insurers for industrial projects most commonly request three categories of documentation: the CE certificate for each fire door product, the underlying classification report from an accredited fire-testing laboratory, and the declaration of performance issued by the manufacturer. Together, these documents confirm that the door has been independently tested, classified, and placed on the market under the EU Construction Products Regulation.
In practice, an insurer reviewing a passive fire protection strategy wants to confirm that the doors installed at compartment boundaries are not merely labelled as fire-resistant but have a traceable, documented basis for that claim. The CE certificate shows that the product meets European requirements and carries a classification under EN 13501-2. The classification report from the testing laboratory shows the actual fire test results, including the dimensions tested, the installation configuration, and the exact performance achieved. The declaration of performance is the manufacturer’s formal statement linking the product to its certificate and test data.
Beyond these three core documents, some insurers also ask for evidence that the specified dimensions fall within the extended application range of the tested product. This matters because a fire door classified for a certain opening size may not retain that classification if the installed opening exceeds the range covered by the original test and its extended application rules under EN 15269. If the project involves sector-specific regulation such as PGS15 for chemical storage, additional documentation confirming compliance with those requirements may also be requested.
Facility managers and specifying architects working with Metacon-Next fire-rated industrial doors can request the full documentation package at the specification stage, including CE certificates, Efectis classification reports, and declarations of performance, before any commitment is made.
Need advice for your project?
Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.
What fire resistance classifications satisfy industrial insurers?
There is no single classification that universally satisfies industrial insurers. The classification an insurer accepts depends on the fire safety design for the specific building, the applicable sector regulations, and any above-statutory requirements the insurer itself imposes. What matters is that the installed door carries a documented classification under EN 13501-2 that aligns with the project’s compartmentalisation requirements.
Under EN 13501-2, fire door performance is described using three criteria: E (integrity, meaning flames and hot gases are stopped), W (radiation reduction, which limits radiant heat transfer through the door and represents the Dutch standard baseline criterion), and I (insulation, which limits temperature rise on the unexposed side). The insulation criterion must always be specified as either EI1 or EI2, as these represent different strictness levels. EI1 applies a stricter limit on temperature rise; EI2 permits a higher temperature rise on the unexposed side. A door classified EI1-60 and one classified EI2-60 carry the same duration but differ meaningfully on the insulation criterion, which can affect suitability for a given compartment boundary.
Common classifications found in industrial fire door specifications include EW60, EW90, EW120, EI2-60, EI2-90, EI1-60, and EI1-120. Whether any of these classifications is sufficient for a specific project depends on the compartmentalisation calculation for that building, not on a general rule. Sector-specific regulations such as PGS15 for hazardous substance storage can require a heavier classification than the regulatory baseline. Client requirements and insurer requirements can impose the same. A qualified fire safety engineer should confirm the required classification for each project.
What insurers consistently look for is not a particular classification number but evidence that the classification is documented, independently tested, and applicable to the installed dimensions and configuration.
How does a classification report differ from a CE declaration?
A classification report is the detailed technical record of the fire test itself, produced by an accredited laboratory. A CE declaration of performance is the manufacturer’s formal statement that the product meets the requirements linked to its certificate. The classification report is the evidence; the declaration of performance is the manufacturer’s commitment based on that evidence.
The classification report documents what actually happened during the standardised fire test conducted under EN 1634-1. It records the door configuration tested, the opening dimensions, the hardware used, the installation conditions, and the performance achieved across the E, W, and I criteria. It also defines the extended application range under EN 15269, which determines how far the tested result can be applied to similar but untested configurations. For an architect or insurer reviewing a specification, the classification report answers the question: under exactly what conditions was this classification achieved?
The declaration of performance, by contrast, is a document the manufacturer issues under the EU Construction Products Regulation. It declares the product’s performance characteristics and links the product to its CE certificate and the underlying test data. It is the manufacturer’s legal statement that the product as supplied corresponds to the tested and certified system.
Both documents serve distinct functions in a compliance file. The CE declaration confirms market placement under the CPR. The classification report provides the technical foundation that makes that declaration meaningful. Requesting only one of the two leaves a documentation gap. Architects and facility managers specifying fire doors for industrial projects should request both, along with the CE certificate number, at the specification stage rather than after the order is placed.
Metacon-Next classification reports are issued by Efectis, an internationally accredited fire-safety testing organisation. Each product line in the Metacon-Next range has a corresponding Efectis report number that can be referenced in permit files and insurance documentation.
Do insurers require EPDs for fire-rated industrial doors?
Environmental Product Declarations are not a standard insurance requirement for fire-rated industrial doors. Insurers assessing passive fire protection focus on fire performance documentation rather than lifecycle environmental data. However, EPDs are increasingly requested in European tenders, BREEAM- and LEED-certified projects, and client sustainability reporting, so their availability can be relevant to the broader project file.
An EPD is a standardised environmental document that quantifies a product’s environmental impact across its full lifecycle, from raw material extraction through manufacturing, use, and end-of-life processing. It is based on ISO 14044 and EN 15804. Importantly, an EPD is an information document, not an environmental label or sustainability award. It provides quantified data; it does not pass judgement on whether a product’s environmental performance is good or bad.
For industrial projects pursuing BREEAM or LEED certification, an EPD for the fire door product may be requested as part of the materials documentation. In this context, having an EPD available at the specification stage avoids delays later in the project. Metacon-Next published EPDs for eleven of its main product lines in 2025, covering products including the RGT roller curtain range, the RGS roller door range, the RGC compact roller door, and the OHD-C overhead door lines. The OHD-C Sprint and SGC EI1 60 / EW 120 do not currently have their own EPD in the published documentation.
If an insurer or project owner specifically requests environmental documentation alongside fire performance certificates, EPD availability becomes a practical factor in product selection. For most insurance purposes, however, the CE certificate, classification report, and declaration of performance remain the primary documents.
Need advice for your project?
Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.
What happens if fire door documentation is incomplete at the time of a claim?
Incomplete fire door documentation at the time of an insurance claim can complicate or delay the claims process and, in serious cases, may affect the outcome of the claim. If an insurer cannot verify that the installed fire doors were correctly specified, certified, and installed in accordance with their tested configuration, questions arise about whether the passive fire protection strategy performed as intended.
The core risk is traceability. A fire door that lacks a traceable CE certificate, classification report, or declaration of performance cannot be confirmed as a tested and classified system. If a loss occurs and the insurer’s assessors cannot establish that the compartment boundaries were formed by properly documented fire-resistant assemblies, the insurer may question whether the risk was managed in accordance with the policy conditions or the agreed fire safety design.
Documentation gaps are most commonly caused by one of three situations. First, the specification was made without requesting documentation from the manufacturer before the order was placed, leaving the project team to chase paperwork retrospectively. Second, the installed dimensions fall outside the extended application range of the tested product, meaning the classification stated on the certificate does not technically apply to the opening as built. Third, the documentation exists but was not retained in the building’s maintenance and compliance file, making it unavailable when needed.
The practical consequence of any of these gaps is that the burden of proof shifts. Without documentation, demonstrating that a door assembly performed correctly becomes significantly harder. For facility managers responsible for maintaining compliance files, this underlines the importance of collecting and retaining the full documentation package at the time of installation, not after an incident has occurred.
Working with a manufacturer that makes documentation available proactively reduces this risk. The Metacon-Next product range is supported by CE certificates, Efectis classification reports, and declarations of performance that can be included in permit files, insurance documentation, and building compliance records from the outset of a project. For projects with sustainability reporting requirements, EPDs published in 2025 are available for most product lines.
If you are preparing a fire door specification for an industrial project and want to confirm which documentation is available for a specific product or opening configuration, contact Metacon-Next directly or request a quotation with the relevant technical details. The company’s in-house R&D team and dealer network can support specification queries at any stage of the design process.
Related Articles
- How do you translate a fire-separation requirement into the required fire-resistance rating for a door?
- How do fire compartmentation rules change for mixed-use buildings?
- What is EN 1634-1 and why does it matter for fire doors?
- How does an automatic fire door work in a production environment?
- How does an automatic fire door close on alarm?