What is the difference between EN 16034 and EN 13241?

Mark Asscheman ·
Certified industrial fire door with dual compliance plaques mounted on charcoal steel surface in a warehouse setting.

EN 16034 and EN 13241 are two separate harmonised European standards, and both apply simultaneously to an industrial fire-resistant door. EN 16034 governs the fire- and smoke-resisting closing function, while EN 13241 governs the door as an industrial product regardless of whether it has a fire classification. Neither standard replaces the other, and a manufacturer cannot choose between them.

For architects and specification writers, understanding this distinction matters because each standard addresses different performance criteria, different testing obligations, and different aspects of the CE marking file. The sections below work through the most common questions that arise when specifying fire-rated industrial doors under these two standards.

Which standard applies to which type of door?

EN 13241 applies to all industrial, commercial, and garage doors and gates, regardless of whether they have a fire classification. EN 16034 applies specifically to fire-resisting and smoke-control doors, gates, and openable windows. An industrial fire-resistant door falls under both standards at the same time: EN 13241 because it is an industrial door, and EN 16034 because it provides fire resistance.

This dual applicability is not a technicality that manufacturers can navigate around. The Construction Products Regulation requires that a product placed on the EU market carries CE marking that accounts for all relevant harmonised standards. For a fire-rated roller door, sectional door, or sliding fire door used in an industrial facility, that means demonstrating conformity under EN 13241 and EN 16034 simultaneously.

EN 13241 covers the general mechanical and operational performance of industrial doors: wind load resistance, structural integrity, safe opening and closing behaviour, resistance to water penetration, and thermal transmittance, among other criteria. These requirements apply whether the door is fire-rated or not. EN 16034 then adds the fire- and smoke-resisting closing function on top of that baseline.

It is worth noting that EN 13241 was formerly designated EN 13241-1:2003+A1:2011. Since 2016 it has been designated EN 13241:2003+A2:2016, and the suffix “-1” has been dropped. The correct designation to use in specifications and documentation is EN 13241.

Need advice for your project?

Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.

Contact us

What does EN 16034 actually certify about a fire door?

EN 16034 is the harmonised standard that enables CE marking for the fire-resisting and smoke-control closing function of doors, gates, and openable windows. It does not itself define the fire-resistance classification. Instead, it establishes the framework under which a door’s tested fire performance, determined through EN 1634-1 and classified under EN 13501-2, can be declared in a CE marking context.

The fire-resistance classification that appears on a CE certificate for an industrial fire door is expressed in the terminology of EN 13501-2: the criteria E (integrity), W (radiation reduction), EI1 (insulation under the stricter criterion), and EI2 (insulation under the less strict criterion), each combined with a time duration in minutes. For example, a door classified EW 120 under EN 13501-2 maintains integrity and limits radiant heat transfer for 120 minutes. The W criterion is the Dutch standard baseline classification. A door classified EI2-60 maintains integrity and limits temperature rise on the unexposed side according to the EI2 criterion for 60 minutes.

What EN 16034 certification confirms is that the manufacturer has followed the correct route: fire testing to EN 1634-1, extended application assessment under EN 15269 where applicable, classification under EN 13501-2, and a Declaration of Performance that formally declares the door’s performance characteristics. The CE certificate number issued under EN 16034 is the audit trail that connects the door on site to the test evidence in the laboratory.

For architects closing a permit file or responding to a building inspector, the CE certificate under EN 16034 is the document that demonstrates the fire-resisting closing function has been assessed through an accredited route. The underlying classification report from the testing laboratory provides the technical detail behind that certificate, including which dimensions were tested and how far extended application reaches.

Can a door carry CE marking under both EN 16034 and EN 13241?

Yes. An industrial fire-resistant door must carry CE marking that reflects both EN 16034 and EN 13241. These standards are not alternatives: they address different aspects of the same product, and a CE marking file for an industrial fire door is expected to account for both. This is a requirement of the Construction Products Regulation, not an optional enhancement.

In practice, this means that the CE documentation for an industrial fire door contains declarations covering the performance criteria from both standards. The fire-resistance classification, EW 60, EI1 60, EI2 90, and so on, is declared under EN 16034 and EN 13501-2. The general industrial door performance characteristics, such as wind load class, structural integrity, and operational safety, are declared under EN 13241.

Architects and specification writers reviewing a CE certificate or Declaration of Performance for an industrial fire door should expect to see references to both standards. If a certificate references only EN 16034 without EN 13241, or only EN 13241 without EN 16034, that is a documentation gap worth investigating before the product is committed to a specification.

Metacon-Next’s fire-rated industrial door range is CE-certified under both standards, with classification reports from Efectis providing the technical basis for each fire-resistance classification. The CE certificate numbers and Efectis report numbers are available in the product documentation, which architects can request at the specification stage rather than after an order is placed.

What are the key differences in testing requirements between the two standards?

The key difference is that EN 16034 requires fire-resistance testing and classification, while EN 13241 requires testing of general mechanical, structural, and operational performance characteristics. Neither standard tests for the same things, which is precisely why both are required simultaneously for an industrial fire door rather than one replacing the other.

Testing under EN 16034

EN 16034 relies on fire-resistance testing conducted to EN 1634-1, the test method for fire-resistance of door and shutter assemblies. During this test, the door assembly is exposed to a standardised fire curve, and its performance is measured against the relevant criteria: E (integrity), W (radiation reduction), and I (insulation, distinguished as I1 or I2). The duration over which the door maintains each criterion determines the classification.

Where a door has not been individually tested in every possible configuration, extended application rules under EN 15269 allow test results to be applied to similar but untested configurations, within defined limits. These limits are described in the classification report and determine the range of dimensions and configurations for which the classification remains valid. If a specified opening exceeds those limits, the classification cannot be applied, and a separately tested or assessed solution is required.

Testing under EN 13241

EN 13241 requires assessment of a broader set of performance characteristics relevant to industrial doors in general use. These include resistance to wind load, structural integrity under operational loads, resistance to water penetration, thermal transmittance, safe behaviour during operation, and endurance under repeated cycling. The specific characteristics that must be declared depend on the door type and its intended use.

These tests are not fire tests. They address how the door performs during normal day-to-day operation and under environmental loads. For a door installed at a logistics centre or production facility, demonstrating adequate wind load resistance and operational safety is a separate compliance obligation from demonstrating fire resistance, and EN 13241 is the standard through which that obligation is met.

Need advice for your project?

Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.

Contact us

How do these standards affect what architects must specify?

Architects specifying fire-rated industrial doors must ensure that the product they specify is CE-marked under both EN 16034 and EN 13241, that the fire-resistance classification in the specification matches the tested and certified classification for the actual door assembly, and that the specified dimensions fall within the extended application range confirmed in the classification report. Specifying a fire class without confirming the supporting documentation is insufficient for a defensible specification.

The classification report is the document that makes or breaks this process. It contains the test conditions, the classification result, and the extended application limits, including the maximum dimensions for which the classification holds. An architect cannot apply a fire-resistance classification to an opening that exceeds the tested and extended range without either obtaining a separately tested solution or commissioning a specific technical assessment. A generic product drawing does not substitute for a classification report that confirms the classification applies to the specified configuration.

Documentation should be requested at the specification stage, not after the order is placed. If a manufacturer cannot supply the CE certificate, the classification report, and the Declaration of Performance before commitment to a product, that is a signal worth taking seriously. For projects with BREEAM or LEED sustainability requirements, Environmental Product Declarations are an additional documentation requirement to consider.

The distinction between EN 16034 and EN 13241 also has a practical consequence for the specification document itself. A specification that references only one of the two standards is incomplete. Both standards should be cited in the performance specification for an industrial fire door, with the fire-resistance classification expressed in EN 13501-2 terminology, specifying EI1 or EI2 explicitly rather than writing a generic EI classification, and noting the required duration in minutes.

Whether a particular fire-resistance classification is sufficient for a specific compartmentalisation requirement depends on the project’s fire safety calculation and cannot be determined from the door classification alone. The applicable requirement should be confirmed with a qualified fire safety engineer or the competent authority for the project. For questions about available classifications, extended application limits, or documentation for a specific opening, contact Metacon-Next directly: the in-house R&D team and dealer network can provide technical support at the specification stage.

Metacon-Next manufactures fire-rated industrial doors across a range of types including roller curtains, roller doors, overhead doors, sliding doors, and pedestrian doors, all CE-certified and tested by Efectis. Classification reports, CE certificates, Declarations of Performance, and EPDs published in 2025 are available for the main product lines, giving architects the complete documentation package needed to close a specification file with confidence. To explore the full range or request a quotation, the Metacon-Next website provides product information and direct access to the team.