Which Declarations of Performance and CE documents are required under EN 16034 and EN 13241?

Mark Asscheman ·
Compliance dossier with stamped certification seals fanned open on a drafting table, fire-rated steel door visible in the background.

Under EN 16034 and EN 13241, a CE marking package for a fire-rated industrial door consists of two parallel sets of documentation: a Declaration of Performance issued under each applicable standard, supported by the underlying classification report from an accredited testing laboratory. Both standards apply simultaneously to industrial fire doors: EN 16034 covers the fire-resisting closing function, while EN 13241 covers the door as an industrial product, and neither replaces the other. The sections below work through the specific documents required, what each must contain, how the two standards divide responsibility, and when a specified opening dimension can invalidate the classification entirely.

What documents make up a CE marking package under EN 16034 and EN 13241?

A complete CE marking package for a fire-rated industrial door includes a Declaration of Performance under EN 16034, a Declaration of Performance under EN 13241, the underlying Efectis classification report that substantiates the fire-resistance classification, and the CE marking itself affixed to the product or its packaging. Because both standards apply simultaneously to industrial fire doors, both Declarations of Performance are required, not one or the other.

Each of these documents serves a distinct function. The Declaration of Performance under EN 16034 formally declares the fire-resisting and smoke-control performance of the door assembly. The Declaration of Performance under EN 13241 declares the general industrial door characteristics, mechanical endurance, wind resistance, thermal transmittance, and related properties, that apply to any industrial door regardless of its fire classification. The classification report is the technical foundation behind the EN 16034 DoP: it records the actual fire-test results from the accredited laboratory, the conditions under which the classification was achieved, and the extended application range within which the classification remains valid.

The CE marking itself is the visible output of this process. It signals that the manufacturer has declared conformity with the applicable harmonised standards and taken responsibility for the product’s stated performance. Without the supporting documentation behind it, the CE mark carries no verifiable meaning. Architects and specification writers should therefore always request the full documentation package, not just the CE mark, at the specification stage, before any commitment to a product is made.

Metacon-Next publishes its CE certificates, classification reports, and EPDs openly, so that specifiers working on fire-rated industrial door projects can close a specification file without chasing paperwork after the order is placed.

Need advice for your project?

Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.

Contact us

What information must a Declaration of Performance contain for a fire-rated door?

A Declaration of Performance for a fire-rated door must identify the product type, the applicable harmonised standard, the notified body that assessed conformity, the declared performance characteristics, and the unique product identification code. For an industrial fire door, the DoP under EN 16034 must state the fire-resistance classification, expressed in accordance with EN 13501-2, including the performance criterion (E, EW, EI1, or EI2) and the duration in minutes.

The fire-resistance classification stated in the DoP must match the classification achieved in the underlying test and confirmed in the classification report. It is not a self-declared value: it is the manufacturer’s formal declaration of a tested and assessed outcome. This means the DoP is only as reliable as the classification report behind it, which is why the classification report must be requested alongside the DoP rather than treated as a separate or optional document.

For the DoP to be meaningful to an architect or specifier, it must also be traceable. The certificate number references the notified body that assessed the product: for example, the prefix 1812 in certificate numbers such as 1812-CPR-1774 refers to the certifying body involved. This traceability allows a permit authority, building inspector, or insurer to verify the declared performance independently.

The EN 13241 DoP for the same door declares a different set of performance characteristics: those relevant to the door as an industrial product. These include mechanical endurance, wind load resistance, and thermal transmittance, among others. Neither DoP is a substitute for the other, and a complete specification file requires both.

How do EN 16034 and EN 13241 divide responsibilities?

EN 16034 and EN 13241 divide responsibility by subject matter, not by product type. EN 16034 governs the fire-resisting and smoke-control closing function of the door: it concerns what the door does when a fire occurs. EN 13241 governs the door as an industrial product in normal operational conditions: it concerns how the door performs day to day. Both standards apply simultaneously to any industrial door that also carries a fire-resistance classification.

This dual-standard structure reflects the fact that a fire-rated industrial door must satisfy two distinct sets of requirements. Under EN 13241, the door must meet performance thresholds for mechanical operation, structural integrity under wind load, and other properties relevant to industrial use. Under EN 16034, the same door must demonstrate that its fire-resisting closing function has been tested in accordance with the fire-resistance test method EN 1634-1 and classified under EN 13501-2.

A common misunderstanding is that EN 16034 alone is sufficient for a fire-rated industrial door, or that EN 13241 can be disregarded once a fire classification is in place. Neither is correct. EN 13241 is mandatory for any industrial door placed on the EU market, regardless of whether it carries a fire classification. The fire classification under EN 16034 adds to, rather than replaces, the EN 13241 obligations. Specifiers should confirm that a manufacturer holds valid CE certificates under both standards for the specific product being specified.

The Metacon-Next product range is CE-certified under both EN 16034 and EN 13241, with certificate numbers available for each product line across roller curtains, roller doors, overhead doors, sliding doors, and pedestrian doors.

What is the role of the classification report alongside the DoP?

The classification report is the technical evidence that substantiates the fire-resistance performance declared in the Declaration of Performance. While the DoP states the classification, the classification report proves it, recording the exact test conditions, the dimensions tested, the hardware configuration, and the outcome of the fire resistance test conducted by an accredited laboratory. Without the classification report, the DoP cannot be independently verified.

For architects and specification writers, the classification report serves a function that the DoP alone cannot: it shows the boundary conditions under which the classification was achieved. This matters because a fire-resistance classification is not a universal property of a door model: it is a classification that applies within the tested configuration and the extended application range derived from it. The classification report, together with the extended application rules under EN 15269, defines how far the tested results can be applied to door sizes and configurations that were not individually tested.

Metacon-Next classification reports are issued by Efectis, an internationally accredited fire-safety testing organisation. Each product line has a corresponding Efectis report number. For example, the OHD-C overhead door range carrying EI1 60, EI2 90, and EW 90 classifications is supported by Efectis report 2020-Efectis-R000946, while the heavier OHD-C EI1 120 classification is substantiated by report 2022-Efectis-R000824. The LD Pro pedestrian door range is documented under reports C1396-20-0004-2401-CC and C1396-20-0004-2401-SC, covering the with-frame and without-frame configurations respectively.

Architects should request the classification report at the specification stage, not after the order is placed. If a manufacturer cannot supply the classification report before commitment to a product, that is a meaningful signal about the completeness of their documentation. The classification report is not a supplementary document; it is a core part of the evidence that closes a permit file.

When does a specified opening dimension invalidate the CE classification?

A specified opening dimension invalidates the CE classification when it falls outside the extended application range, known as the EXAP range, derived from the fire test results and defined in the classification report. A door classified EI1 60, for example, retains that classification for any opening dimension within its tested and extended application range. If the specified opening exceeds that range, the classification can no longer be applied to that opening, and the architect must seek a separately tested or assessed solution.

Extended application is governed by EN 15269, which sets out how fire-test results for a specific door configuration can be extrapolated to similar but untested configurations. The rules cover changes in width, height, leaf area, and other dimensional parameters. They do not permit unlimited extrapolation: each product’s EXAP range has defined limits, and those limits are documented in the classification report.

This has a direct consequence for specification practice. An architect cannot apply a single classification drawing across multiple opening sizes without confirming that each size falls within the product’s EXAP range. If an opening in the design exceeds the documented range, the classification stated in the specification is not valid for that opening, even if the same door model is used. This is not a procedural technicality: it is a life-safety consequence, because the classification is the evidence that the door will perform as required during a fire event.

For non-standard or large openings, the appropriate step is to confirm with the manufacturer whether the required dimension falls within the tested and extended application range, or whether an alternative product or separately assessed solution is needed. Metacon-Next’s in-house R&D department and custom manufacturing capability at its Moordrecht facility mean that non-standard openings can often be addressed without sacrificing classification integrity, but this must be confirmed against the documented EXAP limits, not assumed. Specifiers can contact Metacon-Next directly to confirm dimensional applicability before finalising a specification.

Need advice for your project?

Discuss your requirements for fire-rated doors, burglar-resistant roller shutters or a suitable solution with Metacon-Next.

Contact us

What additional documentation supports a complete specification file?

Beyond the Declarations of Performance and the classification report, a complete specification file for a fire-rated industrial door is supported by Environmental Product Declarations, company-level ISO certifications, technical drawings matched to the specified classification, and installation documentation. Each of these serves a distinct purpose in demonstrating due diligence to permit authorities, building inspectors, insurers, and clients.

Environmental Product Declarations

An Environmental Product Declaration is a standardised document quantifying a product’s environmental impact across its full lifecycle, based on ISO 14044 and EN 15804. EPDs are not a legal requirement for CE marking, but they are increasingly requested in European tenders and in projects pursuing BREEAM or LEED certification. Metacon-Next published EPDs for eleven of its main product lines in 2025, covering roller curtains, roller doors, compact roller doors, and overhead doors. The OHD-C Sprint and SGC EI1 60 / EW 120 do not currently have their own EPD in the available documentation. An EPD is an information document: it quantifies environmental impact transparently; it is not an environmental award or sustainability label.

ISO certifications and technical drawings

Metacon-Next holds ISO 9001 (quality management) and ISO 14001 (environmental management) certifications, both renewed in April 2025. These are company-level certifications that apply to the organisation and its production processes: they confirm that quality assurance and environmental management are embedded in how the company operates. They do not certify the fire performance of individual products, and should not be presented as such in a specification file.

Technical drawings are a further requirement that is often underestimated. A fire-rated door specification must include drawings that match the classification stated in the specification: a generic drawing cannot be applied across multiple classifications. The drawing must correspond to the tested configuration, including frame details, hardware, and any special features such as a liquid-tight seal. For projects where BREEAM or LEED documentation is required, the EPD number should be referenced alongside the product specification to ensure the sustainability file is complete.

For architects building a specification file that can be defended throughout the project lifecycle, from permit application to final inspection, the combination of CE certificates under EN 16034 and EN 13241, the Efectis classification report, matched technical drawings, and, where applicable, an EPD represents the full evidential package. Specifiers can request a quotation and access technical documentation for Metacon-Next products directly, or learn more about the company and its certification approach before beginning the specification process.